ORA-16277: specified table is not supported by logical standby database

ORA-16277: specified table is not supported by logical standby database


Cause:


A call was made to DBMS_LOGSTDBY.INSTANTIATE_TABLE to instantiate an unsupported table on the logical standby database. Tables with unsupported data types cannot be replicated to a logical standby database.



Action:


Specify a table which is not listed in the DBA_LOGSTDBY_UNSUPPORTED_TABLE view.