Oracle DBA, How To, Error, Cause and Action

ORA-01321: No Logminer Dictionary for requested start SCN

ORA-01321: No Logminer Dictionary for requested start SCN


Cause:


The requested session start SCN is less than the SCN of any available Logminer Dictionary build. It is not possible to unwind a Logminer Dictionary to the requested start SCN.



Action:


Re-issue the start_logminer request with a start SCN for which a Logminer Dictionary is available.